MTS – 225 is suitable for electrical and electronic products and other products, parts and materials for environmental reliability testing like high temperature test, low temperature test, dry heat test and damp heat test.
Features and benefits
Test Methods and Standards
- GB/T 2423.1-2008 (IEC 60068-2-1:2007, IDT)
- GB/T 2423.2-2008 (IEC 60068-2-2:2007, IDT)
- GB/T 2423.3-2008 (IEC 60068-2-78:2001, IDT)
- GB/T 2423.4-2008 (IEC 60068-2-30:2005, IDT)
- GJB 360.8-2009
- GJB 150.3-2009
- GJB 150.4-2009
- GJB 150.9-2009
Easy to operate
High reliability
Specifications
Temperature |
|
Temperature Range |
18°C~+90°C |
Temperature Uniformity |
≤±2.0°C |
Temperature Fluctuation |
≤±0.5°C |
Temperature Deviation |
≤±2.0°C |
Analytical accuracy |
0.01°C |
Heat-up Time |
From -20°C to +100°C within 35min. No load |
Cool-down Time |
From +20°C to -20°C within 45min. No load |
Humidity |
|
Humidity Range |
20%RH~98%RH |
Humidity Uniformity |
±3.0%RH |
Humidity Fluctuation |
Humidity Fluctuation |
Humidity Deviation |
±3.0%RH (>75%RH) ±5.0%RH (≤75%RH) |
Technical Documents
Technical Data SheetHow can we support you?