Challenges and Solutions to Large-Volume TIM Dispensing
Viscosity Problems
The viscosity of some materials can be inconsistent within a pail, and that variability can gradually change the flow rate. How can this be addressed?
Include Mass Flow Calibration (MFC) and the large capacity weight scale in your configuration to adjust the dispense to the variable flow rate.


Dispensing Volume
Is the dispensed thickness or volume enough to fully contact the opposing surfaces after compressing the material to the required bond line thickness?
Include height sensing in your configuration. Height sensing will detect the substrate height before dispense, and you can use it to perform post-dispense checks for sufficient material thickness in a specific location.
Manual Steps
Do you have a continuous inline production process or a batch process that requires manual steps between different dispensing applications?
Consider the our dual-table dispensing robot DYSR Series. This system lets you unload, load and dispense simultaneously without stopping your process, increasing overall UPH.

High accuracy, repeatability & traceability

Does your process demand high accuracy, repeatability, and traceability, such as in the automotive or medical device industry?
Our Processive Cavity Pump delivers repeatable volumetric accuracy without interruption – and it’s all traceable. When combined with the optional weight scale on the GCC Series, you will also have access to ARC Technology for two-component material dispensing to control metering and mix ratios.